Setting a density tolerance for press profiling in IntelliTrax

The IntelliTrax ICC system allows you to set an acceptable density tolerance across the sheet to be used when creating a press profile. This is a very important feature. If a profile is built from a press sheet in which the densities vary, the profile will not yield acceptable results.

The following sequence of events will allow you to set or change this tolerance.

You will also find two check boxes on this page. "Disable profile button unless tolerance" and "Warn user when profile is out of range". Under normal circumstances these should both be checked. A profile should never be built from a sheet that is out of tolerance.